ATV630U22N4 - frequency converter
new in sealed original packaging
Normal price
13.218,00 Kč
/
- plus taxes + shipping
- Fast delivery
- New & Sealed Original Items
- Manufacturer's warranty on all parts
- Access to stock items available worldwide
- Feedback within 24 hours
- Low stock - 5 items left
- Inventory on the way
Do you need more than what we have in stock? Just ask us.
Series | Altivar Process ATV600 |
---|---|
Product or component type | Variable speed drive |
Product-specific application | Processes and tools |
Short name of the device | ATV630 |
Variant | Standard version |
Product determination | Asynchronous motors Synchronous motors |
EMC filter | Integrated with 50 m motor cable max corresponds to EN/IEC 61800-3 category C2 Integrated with 150 m motor cable max corresponds to EN/IEC 61800-3 category C3 |
Protection class (IP) | IP21 corresponds to IEC 61800-5-1 IP21 corresponds to IEC 60529 |
[UH,nom] Rated operating voltage | 380-480V |
Protection class | UL Type 1 corresponds to UL 508C |
Cooling type | Forced convection |
Mains frequency | 50 - 60 Hz - 5 - 5% |
Nominal operating voltage [U,nom] | 380-480 V -15 - +10% |
Motor power (kW) | 2.2 kW (normal operation) 1.5 kW (heavy duty operation) |
Engine power (HP) | 3 hp normal operation 2 hp heavy duty operation |
Mains power | 4.3 A at 380 V (normal operation) 3.8 A at 480 V (normal operation) 3.1 A at 380 V (heavy duty operation) 2.9 A at 480V (heavy duty) |
Mains short-circuit current Ik | 50 kA |
Apparent power | 3.2 kVA at 480 V (normal operation) 2.4 kVA at 480 V (heavy duty operation) |
Output rated current | 5.6 A at 4 kHz for normal operation 4 A at 4 kHz for heavy duty operation |
Type of motor control asynchronous motor | Constant torque Optimized torque operating mode Variable torque |
Control profile for synchronous motors | Permanent magnet motor Synchronous reluctance motor |
Output frequency | 0.1…500 Hz |
Rated clock frequency | 4 kHz |
Clock frequency | 2 - 12 kHz adjustable 4 - 12 kHz with derating factor |
Safety function | STO (Safe Torque Off) SIL 3 |
Discrete input logic | 16 preset speeds |
Communication protocol | Modbus TCP Modbus, serial Ethernet |
Option card | Slot A: Communication module, Profibus DP V1 Slot A: Communication module, Profinet Slot A: Communication module, DeviceNet Slot A: Communication module, Modbus TCP/EtherNet/IP Slot A: Communication module, CANopen Daisy Chain RJ45 Slot A: Communication module, CANopen SUB-D 9 Slot A: Communication module, CANopen screw terminals Slot A/Slot B: Expansion module for digital and analog I/O Slot A/Slot B: Expansion module for output relay Slot A: Communication module, Ethernet IP/Modbus TCP/MD-Link Communication module, BACnet MS/TP Communication module, Ethernet Powerlink |
Mounting mode | Surface mounting |
---|---|
maximum peak current | 6 A during 60 s (heavy duty operation) 6.2 A during 60 s (normal operation) |
Number of network phases | 3 phases |
Discrete output number | 0 |
Digital output | Relay outputs R1A, R1B, R1C 250 V AC 3000 mA Relay outputs R1A, R1B, R1C 30 V DC 3000 mA Relay outputs R2A, R2C 250 V AC 5000 mA Re relay outputs R2A, R2C 30 V DC 5000 mA Relay outputs R3A, R3C 250 V AC 5000 mA Relay outputs R3A, R3C 30 V DC 5000 mA |
Output voltage | <= Supply voltage |
permissible temporary current gain | 1.1 x In during 60 s (normal operation) 1.5 x In during 60 s (heavy duty operation) |
Slip compensation motor | Automatic, independent of load Adjustable Not available in permanent magnet motor control Can be deactivated |
High and deceleration ramps | Linearly adjustable separately from 0.01-9999 s |
Physical interface | Ethernet 2-wire RS 485 |
Brake to standstill | By direct current supply |
Protection functions | Thermal protection: motor Safe torque off: motor Motor phase failure: motor Thermal protection: drive Safe torque off: drive Overtemperature: drive Overcurrent protection between Output phases and ground: drive Output voltage overload: drive Short circuit protection: drive Motor phase failure: drive Overvoltage protection on the DC bus: drive Overvoltage protection supply voltage: drive Undervoltage detection mains voltage: drive Phase failure detection of the supply voltage: drive Overspeed: drive Interruption detection in the control circuit: drive |
Transmission speed | 10, 100 Mbits 4800,9600,19200 bps, 38.4 Kbps |
Frequency resolution | Display unit: 0.1 Hz Analog input: 0.012/50 Hz |
Transmission frame | RTU |
electrical connection | Control: removable screw terminals 0.5 - 1.5 mm²/AWG 20 - AWG 16 Motor: screw terminal 2.5-6 mm²/AWG 14 - AWG 10 Cable side: screw terminal 2, 5-6 mm²/AWG 14 - AWG 10 |
Connector type | RJ45 (on the decentralized graphical terminal) for Ethernet/Modbus TCP RJ45 (on the decentralized graphical terminal) for Modbus, serial |
Data format | 8 bits, adjustable to odd, even or no parity |
Polarization type | No impedance |
Exchange mode | Half duplex, full duplex, auto-negotiation Ethernet/Modbus TCP |
Number of addresses | 1…247 for Modbus, serial |
Access method | Slave Modbus TCP |
Supply | External power supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short circuit protection Internal supply for setpoint potentiometer (1 to 10 kOhm): 10.5 V DC +/-5%, <10 mA, protection type: overload and short circuit protection Internal power supply for digital inputs and STO: 24 V DC (21…27 V), <200 mA, protection type: overload and short circuit protection |
Local signaling | 3 LEDs for local diagnosis 3 LEDs (two-color) for status of integrated communication 4 LEDs (two-color) for status of communication module 1 LED (red) for presence of voltage |
Width | 144mm |
Height | 350mm |
Depth | 203mm |