ATV630U15N4 - frequency converter

ATV630U15N4 - frequency converter

new in sealed original packaging
Normal price 199.500 Ft
/
  • plus taxes + shipping

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.

  • Fast delivery
  • New & Sealed Original Items
  • Manufacturer's warranty on all parts
  • Access to stock items available worldwide
  • Feedback within 24 hours
  • Low stock - 6 items left
  • Inventory on the way
  • American Express
  • Apple Pay
  • Google Pay
  • Klarna
  • Maestro
  • Mastercard
  • PayPal
  • SOFORT
  • Union Pay
  • Visa

Do you need more than what we have in stock? Just ask us.

Key features

Series Altivar Process ATV600
Product or component type Variable speed drive
Product-specific application Processes and tools
Short name of the device ATV630
Variant Standard version
Product determination Asynchronous motors
Synchronous motors
EMC filter Integrated with 50 m motor cable max corresponds to EN/IEC 61800-3 category C2
Integrated with 150 m motor cable max corresponds to EN/IEC 61800-3 category C3
Protection class (IP) IP21 corresponds to IEC 61800-5-1
IP21 corresponds to IEC 60529
[UH,nom] Rated operating voltage 380-480V
Protection class UL Type 1 corresponds to UL 508C
Cooling type Forced convection
Mains frequency 50 - 60 Hz - 5 - 5%
Nominal operating voltage [U,nom] 380-480 V -15 - +10%
Motor power (kW) 1.5 kW (normal operation)
0.75 kW (heavy duty operation)
Engine power (HP) 2 hp normal operation
1 hp heavy duty operation
Mains power 3 A at 380 V (normal operation)
2.6 A at 480 V (normal operation)
1.7 A at 380 V (heavy duty operation)
1.5 A at 480 V (Heavy duty operation)
Mains short-circuit current Ik 50 kA
Apparent power 2.2 kVA at 480 V (normal operation)
1.2 kVA at 480 V (heavy duty operation)
Output rated current 4 A at 4 kHz for normal operation
2.2 A at 4 kHz for heavy duty operation
Type of motor control asynchronous motor Variable torque
Constant torque
Optimized torque operating mode
Control profile for synchronous motors Permanent magnet motor
Synchronous reluctance motor
Output frequency 0.1…500 Hz
Rated clock frequency 4 kHz
Clock frequency 2 - 12 kHz adjustable
4 - 12 kHz with derating factor
Safety function STO (Safe Torque Off) SIL 3
Discrete input logic 16 preset speeds
Communication protocol Modbus TCP
Ethernet
Modbus, serial
Option card Slot A: Communication module, Profibus DP V1
Slot A: Communication module, Profinet
Slot A: Communication module, DeviceNet
Slot A: Communication module, Modbus TCP/EtherNet/IP
Slot A: Communication module, CANopen Daisy Chain RJ45
Slot A: Communication module, CANopen SUB-D 9
Slot A: Communication module, CANopen screw terminals
Slot A/Slot B: Expansion module for digital and analog I/O
Slot A/Slot B: Expansion module for output relay
Slot A: Communication module, Ethernet IP/Modbus TCP/MD-Link
Communication module, BACnet MS/TP
Communication module, Ethernet Powerlink
Additional features
Assembly mode Surface mounting
maximum peak current 4.4 A during 60 s (normal operation)
3.3 A during 60 s (heavy duty operation)
Number of network phases 3 phases
Discrete output number 0
Digital output Relay outputs R1A, R1B, R1C 250 V AC 3000 mA
Relay outputs R1A, R1B, R1C 30 V DC 3000 mA
Relay outputs R2A, R2C 250 V AC 5000 mA
Re relay outputs R2A, R2C 30 V DC 5000 mA
Relay outputs R3A, R3C 250 V AC 5000 mA
Relay outputs R3A, R3C 30 V DC 5000 mA
Output voltage <= Supply voltage
permissible temporary current gain 1.1 x In during 60 s (normal operation)
1.5 x In during 60 s (heavy duty operation)
Slip compensation motor Can be deactivated
Adjustable
Not available in permanent magnet motor control
Automatic, independent of load
High and deceleration ramps Linearly adjustable separately from 0.01-9999 s
Physical interface Ethernet
2-wire RS 485
Braking until standstill By direct current supply
Protection functions Thermal protection: motor
Safe torque off: motor
Motor phase failure: motor
Thermal protection: drive
Safe torque off: drive
Overtemperature: drive
Overcurrent protection between Output phases and ground: drive
Output voltage overload: drive
Short circuit protection: drive
Motor phase failure: drive
Overvoltage protection on the DC bus: drive
Overvoltage protection supply voltage: drive
Undervoltage detection mains voltage: drive
Phase failure detection of the supply voltage: drive
Overspeed: drive
Interruption detection in the control circuit: drive
Transmission speed 10, 100 Mbits
4800,9600,19200 bps, 38.4 Kbps
Frequency resolution Display unit: 0.1 Hz
Analog input: 0.012/50 Hz
Transmission frame RTU
electrical connection Control: removable screw terminals 0.5 - 1.5 mm²/AWG 20 - AWG 16
Motor: screw terminal 2.5-6 mm²/AWG 14 - AWG 10
Cable side: screw terminal 2, 5-6 mm²/AWG 14 - AWG 10
Connector type RJ45 (on the decentralized graphical terminal) for Ethernet/Modbus TCP
RJ45 (on the decentralized graphical terminal) for Modbus, serial
Data format 8 bits, adjustable to odd, even or no parity
Polarization type No impedance
Exchange mode Half duplex, full duplex, auto-negotiation Ethernet/Modbus TCP
Number of addresses 1…247 for Modbus, serial
Access method Slave Modbus TCP
Supply External power supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short circuit protection
Internal supply for setpoint potentiometer (1 to 10 kOhm): 10.5 V DC +/-5%, <10 mA, protection type: overload and short circuit protection
Internal power supply for digital inputs and STO: 24 V DC (21…27 V), <200 mA, protection type: overload and short circuit protection
Local signaling 3 LEDs for local diagnosis
3 LEDs (two-color) for status of integrated communication
4 LEDs (two-color) for status of communication module
1 LED (red) for presence of voltage
Width 144mm
Height 350mm
Depth 203mm
Product weight 4.5kg