Series | Modicon M221 |
---|---|
Product or component type | Logic Controller |
[UH,nom] Rated operating voltage | 100-240V AC |
Discrete input number | 14, single input corresponds to IEC 61131-2 Type 1 |
Number. analog inputs | 2 at 0 - 10 V |
Discrete output type | Relay normally open |
Discrete output number | 10 relays |
Discrete output voltage | 5 - 125 V DC 5 - 250 V AC |
Discrete output current | 2 A |
Discrete I/O number | 24 |
---|---|
Number of I/O expansion modules | 7 (local I/O architecture) 14 (remote I/O architecture) |
Supply voltage limits | 85…264 V |
Network frequency | 50/60 Hz |
Inrush current | 40 A |
Max.Power consumption in VA | 58 VA at 100-240 V with a limited number of I/O expansion modules 35 VA at 100-240 V without I/O expansion modules |
Power supply output current | 0.52 A 5 V for expansion bus 0.16 A 24 V for expansion bus |
digital logic input | Sink or Source (positive/negative) |
Discrete input voltage | 24V |
Discrete input voltage type | DC |
Resolution of the analog input | 10 bits |
LSB value | 10 mV |
Conversion time | 1 ms per channel + 1 controller cycle for analog input analog input |
permissible overload at the inputs | +/- 30 V DC for 5 min (maximum) for analog input +/- 13 V DC (permanent) for analog input |
Voltage value for guaranteed status 1 | >= 15 V for input |
Voltage value for guaranteed status 0 | <= 5 V for input |
Discrete input current | 7 mA for discrete input 5 mA for fast input |
Input impedance | 3.4 kOhm for discrete input 100 kOhm for analog input 4.9 kOhm for fast input |
[tA] Response time | Switch off for 35 µs, I2 - I5 terminal(s) for input Switch on for 10 ms for outputs Switch off for 10 ms for outputs Switch on for 5 µs, I0, I1, I6, I7 terminal (n) for fast input 35 µs turn on, other terminals Turn off terminal(s) for input 5 µs, I0, I1, I6, I7 Turn off terminal(s) for fast input 100 µs, others Terminals Terminal(s) for input |
configurable filter time | 0 ms for input 3 ms for input 12 ms for input |
Output voltage limits | 125V DC 277V AC |
Max.Current per common output | 4 A at COM 2 7 A at COM 0 7 A at COM 1 |
absolute accuracy error | +/- 1% full scale value for analog input |
Electrical lifespan | 100000 cycles AC-12, 120 V, 240 VA, resistive 100000 cycles AC-12, 240 V, 480 VA, resistive 300000 cycles AC-12, 120 V, 80 VA, ohmic 300000 cycles AC-12, 240 V, 160 VA, ohmic 100000 cycles AC-15, cos phi = 0.35, 120 V, 60 VA, inductive 100000 cycles AC-15, cos phi = 0.35, 240 V, 120 VA, inductive 300000 cycles AC-15, cos phi = 0.35, 120 V, 18 VA, inductive 300000 cycles AC-15, cos phi = 0, 35, 240 V, 36 VA, inductive 100000 cycles AC-14, cos phi = 0.7, 120 V, 120 VA, inductive 100000 cycles AC-14, cos phi = 0.7, 240 V , 240 VA, inductive 300000 cycles AC-14, cos phi = 0.7, 120 V, 36 VA, inductive 300000 cycles AC-14, cos phi = 0.7, 240 V, 72 VA, inductive 100000 cycles DC-12, 24 V, 48 W, ohmic 300000 cycles DC-12, 24 V, 16 W, ohmic 100000 cycles DC-13, 24 V, 24 W, inductive ( L/R = 7 ms) 300000 cycles DC-13, 24 V, 7.2 W, inductive (L/R = 7 ms) |
Clock frequency | 20 switching operations/minute with maximum load |
Mechanical lifespan | 20000000 cycles for relay output |
Minimum load | 1 mA at 5 V DC for relay output |
Protection class | Without protection at 5 A |
Reset time | 1 s |
Storage capacity | 256 kB for user application and data RAM with 10000 instructions 256 kB for internal variables RAM |
Data saved | 256 kB built-in flash memory for backup of application and data |
Data storage device | 2 GB SD card (Optional) |
Battery type | BR2032 or CR2032X Lithium, non-rechargeable |
Backup duration | 1 year at 25 °C (due to interruption of the power supply) |
Execution time for 1 K instruction | 0.3 ms for event and periodic task |
Execution time per instruction | 0.2 µs boolean |
Exact time for event task | 60 µs response time |
Maximum size of the object areas | 255%TM time relay 512%M memory bits 8000%MW words/memory 255%C counter 512%KW constant words |
Real-time clock | With |
Clock deviation | <= 30 s/month at 25 °C |
Control loop | Adjustable PID controller up to 14 simultaneous loops |
Counting input number | 4 Fast input (HSC mode) at 100 kHz 32 bits |
Counting function | A/B Single phase Pulse/Direction |
Integrated connection type | USB port with mini B USB 2.0 port Non-isolated serial connection Serial 1 with RJ45 port and RS232/RS485 interface Ethernet with RJ45 port |
Supply | (Serial)Supply serial interface: 5 V, <200 mA |
Transmission speed | 1.2 - 115.2 kBit/s (115.2 kBit/s standard) for a bus length of 15 m for RS485 1.2 - 115.2 kBit/s (115 .2 kBit/s standard) for a bus length of 3 m for RS232 480 Mbit/s for USB |
Communication protocol | USB port: USB protocol - SoMachine network Non-isolated serial connection: Modbus protocol master/slave - RTU/ASCII or SoMachine network : Ethernet protocol |
Ethernet port | 10BASE-T / 100BASE-TX 1 port with 100 m copper cable |
Communication service | Modbus TCP server MODBUS TCP slave device DHCP client Modbus TCP client EtherNet/IP adapter |
Local signaling | 1 LED (green) for PWR 1 LED (green) for OPERATION 1 LED (red) for module error (ERR) 1 LED (green) for SD card access (SD ) 1 LED (red) for BAT 1 LED per channel (green) for I/O status 1 LED (green) for SL Ethernet network activity (green) for ACT Ethernet network connection (yellow) for connection (connection status) |
Electrical connection | Removable screw terminal block for inputs Removable screw terminal block for outputs Terminal block, 3 terminal(s) for connecting the 24 V DC power supply Plug, 4 terminal(s) for analog inputs Mini B USB 2.0 connector for a programming device |
Maximum cable distance between devices | Shielded cable: <10 m for fast input Unshielded cable: <30 m for outputs Unshielded cable: <30 m for digital input Unshielded cable: <1 m for analog input |
Isolation | Between input and internal logic at 500 V AC Not isolated between analog input and internal logic Not isolated between analog inputs Between supply and ground at 1500 V AC Between sensor Power supply and ground at 500 V AC Between input and ground at 500 V AC Between output and ground at 1500 V AC Between supply and internal logic at 2300 V AC Between sensor power supply and internal Logic at 500 V AC Between output and internal logic at 2300 V AC Between Ethernet terminal and internal logic at 500 V AC Between supply and sensor power supply at 2300 V AC |
Label | CE |
Sensor power supply | 24 V DC at 250 mA provided by the controller |
Mounting bracket | Cylinder head type TH35-15 rail corresponds to IEC 60715 Th35-7 top hat rail.5 rail corresponds to IEC 60715 sheet metal or panel with fittings |
Height | 90mm |
Depth | 70mm |
Width | 110mm |
Product weight | 0.395kg |