ATV930U22N4 - frequency converter

ATV930U22N4 - frequency converter

new in sealed original packaging
Normal price 6.014,00 kr
/
  • plus taxes + shipping

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.

  • Fast delivery
  • New & Sealed Original Items
  • Manufacturer's warranty on all parts
  • Access to stock items available worldwide
  • Feedback within 24 hours
  • Low stock - 6 items left
  • Inventory on the way
  • American Express
  • Apple Pay
  • Google Pay
  • Klarna
  • Maestro
  • Mastercard
  • PayPal
  • SOFORT
  • Union Pay
  • Visa

Do you need more than what we have in stock? Just ask us.

Key features

Series Altivar Process ATV900
Device Application Industrial application
Product or component type Variable speed drive
Product determination Synchronous motors
Asynchronous motors
Product-specific application Process for industrial
Variant Standard version
With brake chopper
Number of network phases 3 phases
Assembly mode Surface mounting
Communication protocol Modbus TCP
EtherNet/IP
Modbus, serial
Nominal operating voltage [U,nom] 380-480 V -15 - +10%
Motor power (kW) 2.2 kW for normal operation
1.5 kW for heavy duty operation
Output rated current 5.6 A at 4 kHz for normal operation
4 A at 4 kHz for heavy duty operation
EMC filter Integrated
With EMC plate option
IP protection class IP21
Protection class UL Type 1
optional module Slot A: Communication module for Profibus DP V1
Slot A: Communication module for Profinet
Slot A: Communication module for DeviceNet
Slot A: Communication module for EtherCAT
Slot A: Communication module for CANopen Daisy Chain RJ45
Slot A: Communication module for CANopen SUB-D 9
Slot A: Communication module for CANopen screw terminals
Slot A/Slot B/Slot C: Expansion module for digital and analog I/O
Slot A/Slot B/Slot C: Expansion module for output relay
Slot B: 5/12 V digital encoder interface module
Slot B: Analog encoder interface module
Slot B: Interface module for encoder with actual value feedback
Communication module for Ethernet Powerlink
Number of preset speeds 16 preset speeds
Type of motor control asynchronous motor Constant torque
Optimized torque operating mode
Variable torque
Control profile for synchronous motors Permanent magnet motor
Synchronous reluctance motor
max.Output frequency 599 Hz
Clock frequency 2 - 16 kHz adjustable
4 - 16 kHz with derating factor
Rated clock frequency 4 kHz
Mains power 4.3 A at 380 V (normal operation)
3.1 A at 380 V (heavy duty operation)
3.8 A at 480 V (normal operation)
2.9 A at 480V (heavy duty operation)
Apparent power 3.2 kVA at 480 V (normal operation)
2.4 kVA at 480 V (heavy duty operation)
maximum peak current 6.7 A during 60 s (normal operation)
6 A during 60 s (heavy duty operation)
Network frequency 50 - 60 Hz
Mains short-circuit current Ik 50 kA
Additional features
Discrete input number 10
Digital input DI1 - DI8 programmable, 24 V DC (<= 30 V), impedance: 3.5 kOhm
DI7, DI8 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V )
STOA, STOB Safe Torque Off (safe torque off), 24 V DC (<= 30 V), impedance: > 2.2 kOhm
Discrete output number 2
Digital output Logic output DQ+ 0…1 kHz <= 30 V DC 100 mA
Programmable as pulse output DQ+ 0…30 kHz <= 30 V DC 20 mA
Logic output DQ- 0…1 kHz <= 30 V DC 100 mA
Number of analog inputs 3
Measuring inputs AI1, AI2, AI3 software-configurable voltage: 0 - 10 V DC, impedance: 30 kOhm, resolution 12 bits
AI1, AI2, AI3 software-configurable current: 0-20 mA/4-20 mA, impedance : 250 Ohm, resolution 12 bits
Number of analog outputs 2
Type of analogue output Software-configurable voltage AQ1, AQ2: 0 - 10 V DC resistance 470 ohms, resolution 10 bits
Software-configurable current AQ1, AQ2: 0 - 20 mA resistance 500 ohms, resolution 10 bits
Relay output number 3
Output type of the relay Configurable relay logic R1: fault relay normally open/closed electrical life 100,000 cycles
Configurable relay logic R2: sequence relay normally open (S) electrical service life 1000,000 cycles
Configurable relay logic R3: sequence relay normally open ( S) electrical lifespan 1000000 cycles
maximum switching current Relay output R1 on ohmic load, cos phi = 1: 3 A at 250 V AC
Relay output R1 on ohmic load, cos phi = 1: 3 A at 30 V DC
Relay output R1 on inductive Load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
Relay output R1 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
Relay output R2, R3 on ohmic load, cos phi = 1: 5 A at 250 V AC
Relay output R2, R3 on ohmic load, cos phi = 1: 5 A at 30 V DC
Relay output R2 , R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
Relay output R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms : 2 A at 30 V DC
minimum switching current Relay output R1, R2, R3: 5 mA at 24 V DC
Physical interface Ethernet
2-wire RS 485
Connection type 2 RJ45
1 RJ45
Access method Slave Modbus TCP
Transmission speed 10, 100 Mbits
4.8 kbps
9,600 bit/s
19200 bit/s
Transmission frame RTU
Number of addresses 1…247
Data format 8 bits, adjustable to odd, even or no parity
Polarization type No impedance
4 quadrant operation possible Correct
High and deceleration ramps Linearly adjustable separately from 0.01-9999 s
Slip compensation motor Can be deactivated
Not available in permanent magnet motor control
Adjustable
Automatic, independent of load
Brake to standstill By direct current supply
Brake chopper integrated Correct
Max.Input current 4.3A
Maximum output voltage 480.0V
Relative symmetric network frequency tolerance 5%
Base load current at high overload 4.0A
Base load current at low overload 5.6A
Power loss in W Fanless with convection: 30 W at 380 V, switching frequency 4 kHz
Forced convection: 60 W at 380 V, switching frequency 4 kHz
with Safely Limited Speed ​​(SLS) safety function Correct
with safety function Safe brake management (SBC/SBT) Correct
with Safe Operating Stop (SOS) safety function False
with Safe Position (SP) safety function False
with safety function Safe programmable logic False
with Safe Speed ​​Monitor (SSM) safety function False
with safety function Safe Stop 1 (SS1) Correct
with safety function Safe Stop 2 (SS2) False
with safety function Safe torque off (STO) Correct
with Safely Limited Position (SLP) safety function False
with Safe Direction (SDI) safety function False
Protection functions Thermal protection: motor
Safe torque off: motor
Motor phase failure: motor
Thermal protection: drive
Safe torque off: drive
Overtemperature: drive
Overcurrent protection between Output phases and ground: drive
Overload of the output voltage: drive
Short circuit protection: drive
Motor phase failure: drive
Overvoltage protection on the DC bus: drive
Overvoltage protection supply voltage: drive
Undervoltage detection mains voltage: drive
Phase failure detection of the supply voltage: drive
Overspeed: drive
Interruption detection in the control circuit: drive
Quantity per set 1
Width 144mm
Height 350mm
Depth 206mm
Product weight 4.5kg
This area currently has no content. Add content to this area using the sidebar.

You might also be interested in