ATV930U22N4 - frequency converter
new in sealed original packaging
Normal price
5 861 kr
/
- plus taxes + shipping
- Fast delivery
- New & Sealed Original Items
- Manufacturer's warranty on all parts
- Access to stock items available worldwide
- Feedback within 24 hours
- Low stock - 6 items left
- Inventory on the way
Do you need more than what we have in stock? Just ask us.
Series | Altivar Process ATV900 |
---|---|
Device Application | Industrial application |
Product or component type | Variable speed drive |
Product determination | Synchronous motors Asynchronous motors |
Product-specific application | Process for industrial |
Variant | Standard version With brake chopper |
Number of network phases | 3 phases |
Assembly mode | Surface mounting |
Communication protocol | Modbus TCP EtherNet/IP Modbus, serial |
Nominal operating voltage [U,nom] | 380-480 V -15 - +10% |
Motor power (kW) | 2.2 kW for normal operation 1.5 kW for heavy duty operation |
Output rated current | 5.6 A at 4 kHz for normal operation 4 A at 4 kHz for heavy duty operation |
EMC filter | Integrated With EMC plate option |
IP protection class | IP21 |
Protection class | UL Type 1 |
optional module | Slot A: Communication module for Profibus DP V1 Slot A: Communication module for Profinet Slot A: Communication module for DeviceNet Slot A: Communication module for EtherCAT Slot A: Communication module for CANopen Daisy Chain RJ45 Slot A: Communication module for CANopen SUB-D 9 Slot A: Communication module for CANopen screw terminals Slot A/Slot B/Slot C: Expansion module for digital and analog I/O Slot A/Slot B/Slot C: Expansion module for output relay Slot B: 5/12 V digital encoder interface module Slot B: Analog encoder interface module Slot B: Interface module for encoder with actual value feedback Communication module for Ethernet Powerlink |
Number of preset speeds | 16 preset speeds |
Type of motor control asynchronous motor | Constant torque Optimized torque operating mode Variable torque |
Control profile for synchronous motors | Permanent magnet motor Synchronous reluctance motor |
max.Output frequency | 599 Hz |
Clock frequency | 2 - 16 kHz adjustable 4 - 16 kHz with derating factor |
Rated clock frequency | 4 kHz |
Mains power | 4.3 A at 380 V (normal operation) 3.1 A at 380 V (heavy duty operation) 3.8 A at 480 V (normal operation) 2.9 A at 480V (heavy duty operation) |
Apparent power | 3.2 kVA at 480 V (normal operation) 2.4 kVA at 480 V (heavy duty operation) |
maximum peak current | 6.7 A during 60 s (normal operation) 6 A during 60 s (heavy duty operation) |
Network frequency | 50 - 60 Hz |
Mains short-circuit current Ik | 50 kA |
Discrete input number | 10 |
---|---|
Digital input | DI1 - DI8 programmable, 24 V DC (<= 30 V), impedance: 3.5 kOhm DI7, DI8 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V ) STOA, STOB Safe Torque Off (safe torque off), 24 V DC (<= 30 V), impedance: > 2.2 kOhm |
Discrete output number | 2 |
Digital output | Logic output DQ+ 0…1 kHz <= 30 V DC 100 mA Programmable as pulse output DQ+ 0…30 kHz <= 30 V DC 20 mA Logic output DQ- 0…1 kHz <= 30 V DC 100 mA |
Number of analog inputs | 3 |
Measuring inputs | AI1, AI2, AI3 software-configurable voltage: 0 - 10 V DC, impedance: 30 kOhm, resolution 12 bits AI1, AI2, AI3 software-configurable current: 0-20 mA/4-20 mA, impedance : 250 Ohm, resolution 12 bits |
Number of analog outputs | 2 |
Type of analogue output | Software-configurable voltage AQ1, AQ2: 0 - 10 V DC resistance 470 ohms, resolution 10 bits Software-configurable current AQ1, AQ2: 0 - 20 mA resistance 500 ohms, resolution 10 bits |
Relay output number | 3 |
Output type of the relay | Configurable relay logic R1: fault relay normally open/closed electrical life 100,000 cycles Configurable relay logic R2: sequence relay normally open (S) electrical service life 1000,000 cycles Configurable relay logic R3: sequence relay normally open ( S) electrical lifespan 1000000 cycles |
maximum switching current | Relay output R1 on ohmic load, cos phi = 1: 3 A at 250 V AC Relay output R1 on ohmic load, cos phi = 1: 3 A at 30 V DC Relay output R1 on inductive Load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC Relay output R2, R3 on ohmic load, cos phi = 1: 5 A at 250 V AC Relay output R2, R3 on ohmic load, cos phi = 1: 5 A at 30 V DC Relay output R2 , R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms : 2 A at 30 V DC |
minimum switching current | Relay output R1, R2, R3: 5 mA at 24 V DC |
Physical interface | Ethernet 2-wire RS 485 |
Connection type | 2 RJ45 1 RJ45 |
Access method | Slave Modbus TCP |
Transmission speed | 10, 100 Mbits 4.8 kbps 9,600 bit/s 19200 bit/s |
Transmission frame | RTU |
Number of addresses | 1…247 |
Data format | 8 bits, adjustable to odd, even or no parity |
Polarization type | No impedance |
4 quadrant operation possible | Correct |
High and deceleration ramps | Linearly adjustable separately from 0.01-9999 s |
Slip compensation motor | Can be deactivated Not available in permanent magnet motor control Adjustable Automatic, independent of load |
Brake to standstill | By direct current supply |
Brake chopper integrated | Correct |
Max.Input current | 4.3A |
Maximum output voltage | 480.0V |
Relative symmetric network frequency tolerance | 5% |
Base load current at high overload | 4.0A |
Base load current at low overload | 5.6A |
Power loss in W | Fanless with convection: 30 W at 380 V, switching frequency 4 kHz Forced convection: 60 W at 380 V, switching frequency 4 kHz |
with Safely Limited Speed (SLS) safety function | Correct |
with safety function Safe brake management (SBC/SBT) | Correct |
with Safe Operating Stop (SOS) safety function | False |
with Safe Position (SP) safety function | False |
with safety function Safe programmable logic | False |
with Safe Speed Monitor (SSM) safety function | False |
with safety function Safe Stop 1 (SS1) | Correct |
with safety function Safe Stop 2 (SS2) | False |
with safety function Safe torque off (STO) | Correct |
with Safely Limited Position (SLP) safety function | False |
with Safe Direction (SDI) safety function | False |
Protection functions | Thermal protection: motor Safe torque off: motor Motor phase failure: motor Thermal protection: drive Safe torque off: drive Overtemperature: drive Overcurrent protection between Output phases and ground: drive Overload of the output voltage: drive Short circuit protection: drive Motor phase failure: drive Overvoltage protection on the DC bus: drive Overvoltage protection supply voltage: drive Undervoltage detection mains voltage: drive Phase failure detection of the supply voltage: drive Overspeed: drive Interruption detection in the control circuit: drive |
Quantity per set | 1 |
Width | 144mm |
Height | 350mm |
Depth | 206mm |
Product weight | 4.5kg |