Key features

Product area Modicon M221
Product or component type Logic Controller
[UH,nom] Rated operating voltage 100-240V AC
Discrete input number 24, single input corresponds to IEC 61131-2 Type 1
Number. analog inputs 2 at 0 - 10 V
Discrete output type Relay normally open
Discrete output number 16 relays
Discrete output voltage 5 - 125 V DC
5 - 250 V AC
Discrete output current 2 A
Additional features
Discrete I/O number 40
Number of I/O expansion modules 7 (local I/O architecture)
14 (remote I/O architecture)
Supply voltage limits 85…264 V
Network frequency 50/60 Hz
Inrush current 40 A
Max.Power consumption in VA 70 VA at 100-240 V with a limited number of I/O expansion modules
41 VA at 100-240 V without I/O expansion modules
Power supply output current 0.52 A 5 V for expansion bus
0.24 A 24 V for expansion bus
digital logic input Sink or Source (positive/negative)
Discrete input voltage 24V
Discrete input voltage type DC
Resolution of the analog input 10 bits
LSB value 10mV
Conversion time 1 ms per channel + 1 controller cycle for analog input Analog input
permissible overload at the inputs +/- 30 V DC for 5 min (maximum) for analog input
+/- 13 V DC (permanent) for analog input
Voltage value for guaranteed status 1 >= 15 V for input
Voltage value for guaranteed status 0 <= 5 V for input
Discrete input current 7 mA for discrete input
5 mA for fast input
Input impedance 3.4 kOhm for discrete input
100 kOhm for analog input
4.9 kOhm for fast input
[tA] Response time Switch off for 35 µs, I2 - I5 terminal(s) for input
Switch on for 10 ms for outputs
Switch off for 10 ms for outputs
Switch on for 5 µs, I0, I1, I6, I7 terminal (n) for fast input
35 µs turn on, other terminals Turn off terminal(s) for input
5 µs, I0, I1, I6, I7 Turn off terminal(s) for fast input
100 µs, others Terminals Terminal(s) for input
configurable filter time 0 ms for input
3 ms for input
12 ms for input
Output voltage limits 125V DC
277V AC
Max.Current per common output 7 A
absolute accuracy error +/- 1% full scale value for analog input
Electrical lifespan 100000 cycles AC-12, 120 V, 240 VA, resistive
100000 cycles AC-12, 240 V, 480 VA, resistive
300000 cycles AC-12, 120 V, 80 VA, ohmic
300000 cycles AC-12, 240 V, 160 VA, ohmic
100000 cycles AC-15, cos phi = 0.35, 120 V, 60 VA, inductive
100000 cycles AC-15, cos phi = 0.35, 240 V, 120 VA, inductive
300000 cycles AC-15, cos phi = 0.35, 120 V, 18 VA, inductive
300000 cycles AC-15, cos phi = 0, 35, 240 V, 36 VA, inductive
100000 cycles AC-14, cos phi = 0.7, 120 V, 120 VA, inductive
100000 cycles AC-14, cos phi = 0.7, 240 V , 240 VA, inductive
300000 cycles AC-14, cos phi = 0.7, 120 V, 36 VA, inductive
300000 cycles AC-14, cos phi = 0.7, 240 V, 72 VA, inductive
100000 cycles DC-12, 24 V, 48 W, ohmic
300000 cycles DC-12, 24 V, 16 W, ohmic
100000 cycles DC-13, 24 V, 24 W, inductive ( L/R = 7 ms)
300000 cycles DC-13, 24 V, 7.2 W, inductive (L/R = 7 ms)
Clock frequency 20 switching operations/minute with maximum load
Mechanical lifespan 20000000 cycles for relay output
Minimum load 1 mA at 5 V DC for relay output
Protection class Without protection at 5 A
Reset time 1 s
Storage capacity 256 kB for user application and data RAM with 10000 instructions
256 kB for internal variables RAM
Data saved 256 kB built-in flash memory for backup of application and data
Data storage device 2 GB SD card (Optional)
Battery type BR2032 or CR2032X Lithium, non-rechargeable
Backup duration 1 year at 25 °C (by interrupting the power supply)
Execution time for 1 K instruction 0.3 ms for event and periodic task
Execution time per instruction 0.2 µs boolean
Exact time for event task 60 µs response time
Maximum size of object areas 8000%MW words/memory
255%TM time relay
512%KW constant words
255%C counter
512%M memory bits
Real-time clock With
Clock deviation <= 30 s/month at 25 °C
Control loop Adjustable PID controller up to 14 simultaneous loops
Counting input number 4 Fast input (HSC mode) at 100 kHz 32 bits
Counting function Single phase
A/B
Pulse/Direction
Integrated connection type USB port with mini B USB 2.0 port
Non-isolated serial connection Serial 1 with RJ45 port and RS232/RS485 interface
Ethernet with RJ45 port
Supply (Serial)Supply serial interface: 5 V, <200 mA
Transmission speed 1.2 - 115.2 kBit/s (115.2 kBit/s standard) for a bus length of 15 m for RS485
1.2 - 115.2 kBit/s (115 .2 kBit/s standard) for a bus length of 3 m for RS232
480 Mbit/s for USB
Communication protocol USB port: USB protocol - SoMachine network
Non-isolated serial connection: Modbus protocol master/slave - RTU/ASCII or SoMachine network
: Ethernet protocol
Ethernet port 10BASE-T / 100BASE-TX 1 port with 100 m copper cable
Communication Service DHCP client
Modbus TCP client
EtherNet/IP adapter
Modbus TCP server
MODBUS TCP slave device
Local signaling 1 LED (green) for PWR
1 LED (green) for OPERATION
1 LED (red) for module error (ERR)
1 LED (green) for SD card access (SD )
1 LED (red) for BAT
1 LED per channel (green) for I/O status
1 LED (green) for SL
Ethernet network activity (green) for ACT
Ethernet network connection (yellow) for connection (connection status)
Electrical connection Removable screw terminal block for inputs
Removable screw terminal block for outputs
Terminal block, 3 terminal(s) for connecting the 24 V DC power supply
Plug, 4 terminal(s) for analog inputs
Mini B USB 2.0 connector for a programming device
Maximum cable distance between devices Shielded cable: <10 m for fast input
Unshielded cable: <30 m for outputs
Unshielded cable: <30 m for digital input
Unshielded cable: <1 m for analog input
Isolation Between input and internal logic at 500 V AC
Not isolated between analog input and internal logic
Not isolated between analog inputs
Between supply and ground at 1500 V AC
Between sensor Power supply and ground at 500 V AC
Between input and ground at 500 V AC
Between output and ground at 1500 V AC
Between supply and internal logic at 2300 V AC
Between sensor power supply and internal Logic at 500 V AC
Between output and internal logic at 2300 V AC
Between Ethernet terminal and internal logic at 500 V AC
Between supply and sensor power supply at 2300 V AC
Label CE
Sensor power supply 24 V DC at 250 mA provided by the controller
Mounting bracket Cylinder head type TH35-15 rail corresponds to IEC 60715
TH35-7 top hat rail.5 rail corresponds to IEC 60715
sheet metal or panel with fitting
Height 90mm
Depth 70mm
Width 160mm
Product weight 0.456kg